Synthes tfna inventory

Edit your synforms tfna inventory form form online. Typ

Inventory Control Form 3.5 mm LCP™ Medial Distal Tibia Plates 3.5 mm LCP™ Low Bend Medial Distal Tibia Plates Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. 3.5LCPMDTIBICF001v3 05/22 1Trauma & Extremities. Our Trauma & Extremities portfolio offers comprehensive solutions for the treatment of fractures, deformities, and other orthopaedic traumas. Our wide range of surgical instruments and fixation products are designed to provide solutions tailored to the diverse needs of orthopaedic professionals and patients.Quick guide on how to complete tfna synthes inventory. Forget about scanning and printing out forms. Use our detailed instructions to fill out and eSign your documents online. airSlate SignNow's web-based program is specifically created to simplify the arrangement of workflow and optimize the entire process of proficient document management.

Did you know?

About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ...TN-ADVANCED™ Tibial Nailing System. Product Codes: 03.043.002, 03.043.003, 03.043.004... View More. PRODUCT CODES. DESCRIPTION. The TN-ADVANCED™ Tibial Nailing System (TNA) is an intramedullary nailing system for tibia fractures. This fixation system features design improvements to address previously unmet challenges with intramedullary ...Unfortunately we can't detect an electronic copy of the Instructions for Use (IFU) you are seeking. You can find instructions on how to use this product included with the product packaging.Synthes Tfna Inventory 20112024 Form Fill Out and Sign Printable PDF. Modular hand system implants and. Easily fill away pdf plain, edit, and sign them. Web inventory control form lcp vibrant helical hip system (dhhs) synthes (usa) synthes (canada) ag. Web synthes usa, llc 1101 synthes avenue monument, co 80132 manufactured or distributed by ...The Femoral Recon Nail System is an integrated nailing system designed to adapt to multiple surgical approaches. The FRN System provides the choice of Greater Trochanter (GT) and Piriformis Fossa (PF) entry points and anatomical nail designs to support surgical preferences and facilitate hospital standardization. Contact Us.Patient information: DePuy Synthes (USA) To order: (800) 227-6633 DePuy Synthes (Canada), Ltd. To order: (800) 668-1119 InvenTory ConTrol Form Titanium MatrixNEUROTM implants Titanium MatrixNEUROTM Screws Self-Drilling PaCkage oF 20 04.503.103.20 3 mm 04.503.104.20 4 mm 04.503.105.20 5 mm PaCkage oF 1 04.503.103.01 3 mm 04.503.104.01 4 mmsynthes tfna inventory Inventory Control Form Titanium Cannulated Trochanteric Fixation Nail System SYNTHS (USA) To Order: (800) 5230322 Patient Information: SYNTHS (Canada) Fill NowThe Synthes TFNA is an evolution of the Synthes PFNA. It has many features in common with most proximal femoral nails for fragility fractures, the proximal end has a larger diameter than standard nails to increase fit in osteoporotic bone, distally the end of the short nail is tapered and there is just a single locking bolt to reduce the stress riser at the nail tip …SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J7889-C 2/12 Inventory Control Form Titanium Modular Mini Fragment LCP System 2.0 mm, 2.4 mm and 2.7 mm Instrument and Implant Modules 2.0 mm Titanium Cortex Screws, self-tapping LENGTH LENGTH ...TFNA, corto, lunghezza 170 mm Destra Diam. (mm) Angolo collo femorale 04.037.912S 9 125° 04.037.942S 9 130° 04.037.972S 9 135° 04.037.012S 10 125° 04.037.042S 10 130° 04.037.072S 10 135° 04.037.112S 11 125° 04.037.142S 11 130° 04.037.172S 11 135° 04.037.212S 12 125° 04.037.242S 12 130° 04.037.272S 12 135° TFNA, corto, lunghezza 200 mmBackground: The TFNA (Trochanteric Fixation Nail Advanced) Proximal Femoral Nailing System (DePuy Synthes) is frequently used for intramedullary fixation of proximal femoral fractures. The aim of this study was to evaluate all TFNA implant fractures at a UK trauma unit to ascertain any patient or surgical factors associated with implant failure.SE_793147 AC page 2 / 6 Instructions for Use Femoral Recon Nail, Greater Trochanter B 9 mm Right Left Length 04.033.958S 04.033.959S 280 04.033.960S 04.033.961S 300Synthes products supplied in a non-sterile condition must be cleaned and steam-sterilized prior to surgical use. Prior to cleaning, remove all original packag - ing. Prior to steam-sterilization, place the product in an approved wrap or contain - er. Follow the cleaning and sterilization instruction given by the Synthes brochureAug 20, 2020 · AO Foundation: Final report for biomechanical evaluation of non-augmented nail head elements in surrogate femoral heads [Synthes GmbH: USTRA09022 Trochanteric Fixation Nail—Advanced (TFNA)]. 24. Lambers A, Rieger B, Kop A, et al. Implant fracture analysis of the TFNA proximal femoral nail.Examine your inventory immediately to determine if you have the subject products and quarantine them immediately. DO NOT USE THE SUBJECT PRODUCTS. Ref: 2348044 Page 2 of 3 2. Contact your DePuy Synthes Sales Consultant or contact the customer support services at [email protected] to coordinate the return/credits of the subject ...6. DePuy Synthes RFN-Advanced System Locking Attachment Washer Rationale. 09/30/2020. Windchill Document #0000302371 7. DePuy Synthes RFNA Nail/LAW Static Construct Design Verification Report. 08/08/2022. Windchill Document #0000293480 8. DePuy Synthes, RFN-Advanced System Nail TKA Fit Rationale. 09/30/2020. Windchill Document #0000302370 9.The Trochanteric Fixation Nail-Advanced (TFN-A; Synthes GmbH, Oberdorf, Switzerland) is presented as a “next-generation” solution to the ever-increasing incidence of pertrochanteric and intertrochanteric fractures, particularly in elderly patients with poor bone quality.Instructions for Use (IFU) Johnson & Johnson Institute. Reimbursement Resources. Investigator Initiated Studies. CA Compliance. ASR Recall. . The Advanced Nailing System is a portfolio of nails to treat various …Inventory Control Form FRN-ADVANCED™ - Piriformis Fossa Femoral Recon Nailing System Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): FRN-ADVANCED™ Femoral Recon Nail System, Piriformis Fossa, 9 mm distal diameter, sterile Right Part # Left Part # Length (mm) 04.033.928S 04.033.929S 280 04.033.930S 04.033.931S 300DIAMETER LENGTH. 03.113.024 2.8 mm 250 mm, 95 mm calibration. 3.5 mm Variable Angle Locking Screws, Self-Tapping, T15 Stardrive. LENGTH LENGTH.2 DePuy Synthes Femoral Recon Nail System (FRN) Surgical Technique AO Principles In 1958, the AO formulated four basic principles, which have become the guidelines for internal fixation.1, 2 Anatomic reduction Fracture reduction and fixation to restore anatomical relationships. Early, active mobilization Early, active mobilization of theSynthes products supplied in a non-sterile condition must be cleaExtraktionsset Proximaler Femurnagel Operationstechnik DePuy Synth Inventory Control Form LCP Dynamic Helical Hip System (DHHS) SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J5047-E 2/11 LCP DHHS Compression Screw 211.890 4.5 mm Cortex Screws, self-tapping LENGTH 214.828 28 mm 214.830 30 mm 214.832 32 mm ... TFNA, short, length 170 mm Right Dia. (mm) Femoral Neck An The Titanium Cannulated Adolescent Lateral Entry Femoral Nail is an expert nailing system with radiolucent instrumentation. It includes: End Caps. Easy-to-use instrumentation facilitates the surgical procedure. Standard Locking Screws. 5 mm Recon Screws. Get in Touch with a Sales Consultant. TFNA - Système d'enclouage fémoral proximal Système d

TFN-ADVANCED™ Implant only. ON. Static / Rotational Locking. ON. Please refer to the instructions for use for a complete list of indications, contraindications, warnings and precautions. visualized by pixelmolkerei.ch. Interactive 3D Web application by pixelmolkerei.When it comes to managing your stock inventory, having an efficient and accurate system in place is crucial. One popular option that many businesses turn to is using an Excel-based...Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 ... Procedure: Titanium Cannulated Tibial Nails-EX, with Proximal bend, sterile Patient Information: J7976-F 5/13 Inventory Control Form Titanium Cannulated Tibial Nail-EX, with Proximal bend 8.0 mm diameter LENGTH LENGTH 04.034.231S 255 mm 04.034.234S 270 ...TN-ADVANCED™ Tibial Nailing System. Product Codes: 03.043.002, 03.043.003, 03.043.004... View More. PRODUCT CODES. DESCRIPTION. The TN-ADVANCED™ Tibial Nailing System (TNA) is an intramedullary nailing system for tibia fractures. This fixation system features design improvements to address previously unmet challenges with intramedullary ...

The Synthes TFNA is an evolution of the Synthes PFNA. It has many features in common with most proximal femoral nails for fragility fractures, the proximal end has a larger diameter than standard nails to increase fit in osteoporotic bone, distally the end of the short nail is tapered and there is just a single locking bolt to reduce the stress ...Download. Share. Upload, livestream, and create your own videos, all in HD. This is "Depuy Synthese: Live Surgery - TFNA System" by Orthopaedic Trauma Association on Vimeo, the home for high quality videos and the people who love….Understanding how the MMPI is used to help mental health professionals evaluate and diagnose mental health conditions may help you identify its benefits. Does taking a personality ...…

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. DEPUY SYNTHES: 03.037.004. Quantity Available: 0. Cannu. Possible cause: Inventory Control Form - synthes.vo.llnwd.net. Inventory Control Form Case Information (.

DIAMETER LENGTH. 03.113.024 2.8 mm 250 mm, 95 mm calibration. 3.5 mm Variable Angle Locking Screws, Self-Tapping, T15 Stardrive. LENGTH LENGTH.synthes tfna inventory Inventory Control Form Titanium Cannulated Trochanteric Fixation Nail System SYNTHS (USA) To Order: (800) 5230322 Patient Information: SYNTHS (Canada) Fill NowSynthes que tenha sido contaminado com sangue, tecidos e/ou fluidos/elementos corporais não deve voltar a ser utilizado e deve ser eliminado de acordo com os protocolos do hospital. Mesmo que não aparentem danos, os implantes podem ter pequenos defeitos e padrões de tensão internos susceptíveis de provocar a fadiga do material. Precauções

Inventory Control Form Titanium Variable Angle LCP Distal Radius Plates Drill Bits 310.19 2.0 mm, quick coupling, 100 mm 310.26 2.7 mm, quick coupling, 100 mm 310.509 1.8 mm with depth mark, quick coupling, 110 mm 310.530 2.4 mm, quick coupling, 100 mm 1.8 mm Titanium Variable Angle Locking Buttress Pins, with T8 STARDRIVE Recess LengthDESCRIPTION. The Femoral Neck System (FNS) is a solution for femoral neck fractures where the growth plates have fused or cannot be crossed. Designed for improved angular stability 1 and rotational stability 2 with the intent to reduce reoperations related to fixation complications. Product Specifications. How to Use This Product.

Inventory Control Form 3.5 mm Low Profile Pelvic System Some devices Inventory ontrol orm 3 3 Miscellaneous Implants Instruments Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. 3.5LCPPROXTIBICF001 07/22 219.98 Washer, 7.0 mm 292.20 2.0 mm K-wire, 150 mm, 10/pkg.Synthes products supplied in a non-sterile condition must be cleaned and steam-sterilized prior to surgical use. Prior to cleaning, remove all original packag - ing. Prior to steam-sterilization, place the product in an approved wrap or contain - er. Follow the cleaning and sterilization instruction given by the Synthes “Import-ant ... TFN-ADVANCED is a new nail system for proximal femoral fractures with In our relatively small sample of 8 patients treated forintram This site is published by the DePuy Synthes Companies, which are solely responsible for its content. This site is intended for use by residents of Latin America, Europe, Middle East and Africa, Asia & Pacific only. Craniomaxillofacial Distraction (CMFD) System. Th DePuy Synthes TFN-ADVANCED™ Proximal Femoral Nailing System (TFNA) • Page 3 of 5 Results Results of the testing are summarized below, and comparison of the TFNA System head element options are displayed in Figure 4. • While the lag screw and helical blade are comparable in a center-center placement, the helical blade providesThe Titanium Sternal Fixation System provides internal fixation of the sternum for primary or secondary closure and repair. 1,2. Get in Touch with a Sales Consultant. At the end of this video, you should be able toThe TFNA is available as either a short nail (lengths 170mm,TFNA, corto, longitud 170 mm Derecha Diámetro (m 1. Register the account. Begin by clicking Start Free Trial and create a profile if you are a new user. 2. Upload a file. Select Add New on your Dashboard and upload a file from your device or import it from the cloud, online, or internal mail. Then click Edit. 3. Edit synthes large fragment set inventory sheet form. of DePuy Synthes products. Instruction by a surgeo The overall implant fracture rate was (3.1 % , 25/803). The TFNA fracture rate was (2.2 %, 4/183) and all TFNA implant fractures were atraumatic. The mean time to TFNA fracture was 207 +/- 16.66 days . The shortest time to failure was 191 days which occurred in a patient with a bisphosphonate fracture that underwent a closed reduction - deemed ... DEPUY SYNTHES: 03.010.151. Quantity Available: 0. T25 St[Find right information also solutions for a sThe FRN-ADVANCED System is intended for treatment of fractures i The set screws for the TFNa and TFN are unique as they have two separate pieces. The components are divided into the upper portion, or lock drive, and the lower portion, or lock prong. The lock prong in the TFNa appears smaller and thinner in size than its predecessor, the TFN. A spring has also been added in the TFNa.8 Synthes PFNA/PFNA-II Blade Extraction Technique Guide General Notes – If there is no Proximal Femoral Nail Removal Set for PFN, TFN and PFNA/PFNA-II (01.010.180) available, use the hammer guide (357.117) and the hammer (03.010.124 or 357.026) from the Radiolucent Instrument Set for Expert Tibial Nail (01.004.013) or the DFN Distal …